Ballast BioUV

Price range: € 114,00 through € 1 835,84 HT

The BioUV ballast regulates current to UVC lamps to ensure
reliable ignition, optimal 254 nm output, and
safe electrical protection of the reactor.

Compatibility

  • BioUV: UV10, UV20, UV30, UV40
  • UV170, UV250, UV340
  • UV3000 HO, UV3205 HO, UV4205 HO, UV5205 HO, UV6205 HO, UV6273 HO
  • UV HOME: 2, 3, 4, 6, 9
  • Delta UV: type E or ES 5, 10, 15, 20, 40

Selection & replacement

  • Select the ballast matching the reactor nameplate
  • Replace in case of flickering, hard starting, or overheating
  • Always disconnect power before servicing
  • Use only genuine BioUV parts
- +
SKU ballast-UV Category

All UV sterilizers are designed in such a way that all parts work together as a complete functional system. Care must therefore be taken to use the appropriate BioUV ballasts for the reactor used. Therefore, always use original equipment manufacturers for maintenance.

Electronic BioUV ballasts ensuring maximum UV performance of the lamps

1H2O3 supplies original BioUV ballasts. With a wide range of choices, our BioUV ballasts are used in a variety of equipment.

UV bulbs contain filaments that, in the presence of electricity, produce an electric current that generates ultraviolet radiation at 254 nm. All germicidal lamps require the use of an appropriate external ballast to regulate the current flowing through them.

Maintenance du ballast BioUV

Before any intervention, remember that :

    1. The device must be disconnected from the electrical network before any intervention.
    2. Any intervention on the electrical part of the device must be carried out by a qualified and authorized person.
    3. The light produced by a UV bulb must be carefully protected from direct or indirect prying eyes.

When should you replace?

Only when it stops working.

How is the ballast maintenance operation performed?

Materials needed:

    • Original BioUV Ballast

After stopping and securing your installation, you just have to:

    1. Remove the cable gland to release the lamp cable.
    2. Remove the reactor hood
    3. Unplug the ballast connector.
    4. Replace the old ballast with the new one
    5. Then repeat the steps in the other way around

How to recycle ballast?

The easiest way is to send it to the waste disposal center (check the regulations applicable in your country). Alternatively, when you have a ballast recycle, you can reuse the packaging of the new ballast and, for people using original Bio UV reactors, write “recycling” and then ship for your used ballast to be reprocessed at an approved recycling facility.

  • Pools
  • Spa
  • Freshwater aquariums and ornamental ponds
  • Aquaponics
  • Aquaculture / freshwater fish farming
  • More generally, all fresh, clear waters containing less than 20 mg/L of suspended solids, NTU < 1, and iron < 0.1 mg/L

Germicidal UV bulbs disinfect water effectively. This space-saving solution offers protection against leakage, temperature fluctuations, fouling and breakage. A UV disinfection reactor with good UV quartz sheaths prevents environmental risks over time.

UV Fresh Water Disinfection Reactor UV10 UV20 UV30 UV40 1h2o3

Compact UV Fresh Water Disinfection Reactor UV170 Range UV250 UV340 1h2o3

Fresh Water UV Disinfection Reactor, UV3000HO UV3205HO UV4205HO UV5205HO UV6205HO UV6273HO 1H2O3

Available at any time:

Delivered with: Assembly instructions

Delivery
Shipping is free for all orders over 1200€ in CE. For any order under 250€, an administration fee of 35€ will be charged. When placing the order, please indicate where you would like to have your order delivered.
To qualify for a VAT exemption, companies from EC member countries must provide the name and company and their VAT number.

Delays

  • One week.

Once the order has been placed, the above-mentioned period runs (excluding weeks 31 to 34 and 51 to 52) from the date of receipt of payment and validation of the project plan (including all the options requested in the case of special needs). As soon as the equipment is ready, it will be shipped to you. Road transport requires an average of one week to set up, it can go up to 3 weeks for a container depending on the destination.
Please refer to the supplier’s specific terms and conditions for more information.

Receipt

Upon receipt of the package, in case of damage or missing, you must do :

  • To the carrier: immediate observation and confirmation of reservations by registered letter with acknowledgement of receipt, within 3 days of receipt of goods.
  • To the supplier: complaints about apparent defects or non-conformity of the product delivered with the product ordered or with the delivery note, must be made in writing within 3 days of the arrival of the product.

Please refer to the supplier’s specific terms and conditions for more information.

Returns
Any return of items deemed new by the customer must be made within two weeks of receipt.
Any return of products must be the subject of a formal agreement between the seller and the buyer.
Any product returned without this agreement will be made available to the buyer and will not give rise to a credit note. The costs and risks of the return are always the responsibility of the buyer.*
Please refer to the supplier’s specific terms and conditions for more information.

Shopping Cart
preloader