REUSE manholes with uv disinfection

Wastewater recovery:REUSE H manhole range

Waterproof box plug&play enhanced, automatic cleaning online,, sample collection, free delivery in CE, 5 years warranty!

  • S, M, L & XL sizes
  • Height of the enhancer at choice

On request, customization of reactors according to installation, operation and maintenance constraints (flange diameter, inlet/outlet positioning)

SKU: REUSE-deep-manhole Category:

Reuse your wastewater for agricultural irrigation with the fully equipped REUSE raised manholes

Reuse manholes has been approved by the European Union to meet the latest requirements for agricultural irrigation. These compact units, suitable for installation at the end of the wastewater treatment plant, contain a UV sterilizer specially designed for REUSE quality classes A to D. Thanks to the UV dose delivered, the requirements on the E.coli parameters are guaranteed.

Here are some of the advantages of REUSE manholes :

Waterproof compact structure, which can be placed underground to reach the hydraulic line at the outlet of the treatment plant
Automatic lamp cleaning
Upstream and downstream sampling
5 year warranty.

The different configurations of utilization of the REUSE raised manhole 1h2o3

REUSE Reactor UV range

The REUSE range includes 4 sterilizers: S, M, L and XL. For each reactor, the maximum throughput was calculated for each quality class using highly constrained water, namely:

  • TSS = 35 mg/L
  • Transmittance = 50%
  • E.coli concentration: 100 000 UFC/100ml

Of course, if your wastewater leaving the WWTP is of better quality, the same reactor will be able to handle more flow, or you can choose the lower model.

Where to establish the REUSE reactors?

REUSE reactors should be installed at the outlet of the treatment plant, after the tertiary treatment, in order to ensure that the water to be treated meets the treatment requirements imposed on the treatment plant for the TSS, BOD5 and COD parameters.

Why choose this equipment?

This range of reactors has been specially designed for the reutilization of water at the plant outlet. For this reason, these devices were designed with the following applications in mind:

  • Automatic online cleaning system to reduce the formation of organic and inorganic deposits on quartz sleeves.
  • Upstream and downstream sampling valves to facilitate sampling during regulatory controls
  • Teflon UV sensor: to continuously monitor the UVC radiation of the sterilizer
  • Chemical cleaning quilting: to facilitate maintenance and increase radiation performance
  • Interface with detailed view:
    • UVC radiation in %,
    • System time counter,
    • System boot counter,
    • System states
  • Various voltage-free contacts to complete the supervision
    • General defect
    • Pre-alarm / alarm: Lamp efficiency decrease warning (i.e. UV intensity) / Lamp efficiency limit reached,
    • Lamp failure
    • An additional free ON / OFF contact
REUSE reactors UV disinfection 1h2o3

To avoid a rejection in a sensitive area and/or to respond to a lack of water.

Wastewater reutilization at the end of the wastewater treatment plant for :

    • Direct REUSE: Irrigation, micro-irrigation, watering,
    • Indirect REUT: groundwater supply
    • Agricultural use:
      • Field crops
      • Vegetable farming
      • Prairies
      • Orchards
      • Vineyard
    • Urban use:
      • Golf
      • Green spaces
      • Race track
    • Wetlands maintenance
    • Bathing area protection
    • Washing water for industrial processes
  • Horizontal or vertical installation
  • Automatic lamp cleaning in line and without disassembly
  • Upstream and downstream sampling
  • Upstream and downstream purges
  • Chemical Cleaning Inlet (CIP)
  • LCD interface with UV intensity display,
  • Various voltage-free contacts to complete the supervision
  • Non-chemical treatment: no harmful chemicals need to be added.
  • Easy to install and maintain: automated quartz cleaning to ensure the efficiency of the equipment
  • Economical and energy efficient: low power requirements
  • Acts on a wide range of pathogens, including those resistant to chlorination (certain protozoa such as Cryptosporidium and Giardia).
  • Recognized by regulatory agencies, including the United States Environmental Protection Agency (USEPA).
  • Effective – Destroys 99.99% of microorganisms
  • Ecological: UV does not produce any disinfection by-products that could pollute the environment or limit the reuse of water (as in the case of chlorine or ozone)
  • Reliable: works day and night, 24 hours a day, 7 days a week,
  • Safe for users: no handling of chemicals.Safe for users: no chemical manipulation.
  • Compact and fast treatment: the bacteriological abatement is carried out in the reactor. Water flows through the system without the need for a holding tank or reaction time.
  • Continuous monitoring of disinfection efficiency with remote management to meet operational needs.

Shipping

On-site delivery by truck. The discharge is the responsibility of the customer.

Delays

  • 8 weeks.

Once the order has been placed, the above-mentioned period runs (excluding weeks 31 to 34 and 51 to 52) from the date of receipt of payment and validation of the project plan (including all the options requested in the case of special requests). As soon as the equipment is ready, it will be shipped to you. A road transport requires approximately one week to set up, it can take up to 3 weeks for a container depending on the destination.

  • CE certificate
  • Assembly instructions
  • Operating Manual
  • Detailed technical sheet(s)
  • List of replacement parts and consumables

Under normal use conditions:

    • 5 years, for the stainless steel reactor (materials and welds) except in the case of use in a very corrosive environment (brackish or very salty environment, sea water, proximity of acid and corrosive products, use of hydrochloric acid).
    • 2 years for the whole manhole and its components except for the UV lamp and the quartz sleeve (consumable).

Defects and damage caused by natural wear and tear, external accidents, wrong assembly, improper maintenance, irregular use, inadequate storage, non-respect of the expiration date, intervention by a third party, or modification of the product not provided for or specified by the seller, are excluded from the warranty.

All the equipment in the REUSE range is equipped with upstream and downstream sampling ports fitted with flammable valves. Bacterial analysis should be done within 4 hours of sampling, on an average 24-hour sample kept in a cool place. The tests must be accompanied by a UV transmittance measurement at 254 nm as well as a TSS measurement.

REUSE manholes are delivered ready to be connected. They can be processed in 3 ways:

    • Completely covered (min. 100 mm overhang – max. -190 mm hydraudic wire)
    • Partially covered (working height 1,10 m – hydraudic wire -640 mm)

Simply connect the hydraulic inlet and outlet to the flange collars, and connect the electrical cabinet to the mains (220V, 50/60 Hz)

Different ways of installing REUSE manholes

UV lamp maintenance

The lamps are to be removed from the top of the reactor. Before any intervention, remember that :

  1. UV lamps must be recycled according to the regulations of your country. Do not throw them in the regular or industrial waste, as they contain mercury particles.
  2. When replacing a UV lamp, do not put your fingers on the glass. Cleaning the lamps with alcohol will remove any traces.
  3. The light generated by a UV lamp must be carefully protected from direct or indirect view.

When replacing the UVC lamp, be careful not to put your fingers on the glass. Cleaning the lamps with alcohol will remove any finger marks.

When should replacement of wearing parts be considered?

It is recommended to change the UV lamps after 13,000 hours of operation, to maintain the guarantee of a sufficient level of irradiation. This replacement can be done at the same time as the Quartz UV sleeves (if they are damaged). When the sleeves are properly maintained, experience shows that a replacement every two lamps is sufficient (here every 26000 hours / 3 years for example)

How to recycle UV lamps?

That’s easy! Put the old UV lamp in the new lamp package and, for those using original Bio UV reactors, write “recycling” and then ship your used lamps to an approved recycling facility.

Shopping Cart